ACCREDITED MEASURES
THE PHYSICOCHEMICAL TESTING LABORATORY performs the measurement / monitoring of atmospheric pollutants and emissions at source.Since 2009, RENAR has been accredited
CERTIFICATE OF ACCREDITATION nr. LI 749 of 14.01.2009
A.Attempts in permanent premises
Nr. |
Type / Name of the test |
material / product |
Reference document |
1 |
2 |
3 |
4 |
|
Automatic method |
|
|
1 |
Determination of combustion gas concentrations (CO, CO 2, NO x, SO 2, O 2) |
Residual gaseous effluents (emissions) |
PQ – LC – 04.01 ed.1/rev.1 SR ISO 10396:2001
|
B. Tests in autolaborator
Nr.Crt |
Type / Name of the test |
Material/ product |
Reference document |
|
1 |
2 |
3 |
4 |
|
2 |
Determination of NO and NO 2 concentration by chemiluminescence |
Atmospheric air (emissions) |
PQ – LC – 04.02 ed.1/rev.0 SR EN 14211:2005 |
|
3 |
Determination of CO concentration by non - dispersive spectroscopy inIR |
Atmospheric air (emissions) |
PQ – LC – 04.03 ed.1/rev.0 SR EN 14626:2005 |
|
4 |
Determination of ozone concentration by photometry in UV |
Atmospheric air (emissions) |
PQ – LC – 04.04 ed.1/rev.0 SR EN 14625:2005 |
|
5 |
Determination of SO 2 concentration by fluorescence in UV |
Atmospheric air (emissions) |
PQ – LC – 04.05 ed.1/rev.0 SR EN 14212:2005
|
- Analyzer for NOx : chemiluminescent measurement principle, range 0-10pm, detectable lower limit: ≤0,5 ppb;
- Analyzer for CO :the principle of measuring non-dissipative absorption in IR, range 0-10 ppm, detectable lower limit : ≤1 ppb
- Analyzer for SO 2 : UV fluorescence measurement principle, range 0-10 ppm, detectable lower limit : ≤1 ppb
- Analyzer for O 3 : the UV photometry measurement principle, the 0-10 ppm range, the detectable lower limit : ≤0,5 ppb
- Analyzer for THC (total hydrocarbons), NMHC si CH 4 : FID measurement principle, range: 0-100 ppmC, detectable lower limit : ≤0,5 ppmC
- Analyzer for powder PM10 : the principle of gravimetric measurement
- NO x:chemiluminescent measurement principle, range 0-2500 ppm
- SO 2, CO, CO 2: measurement principle non-dissipative absorption in IR, range: SO 2: 0-3000 ppm; CO: 0-5000 ppm; CO 2: 0-20% vol
- O 2: Paramagnetic measurement principle, range: 0-25% vol