- Reverberation Chamber, (according to ISO 3741 and ISO 354): volume of 202,4 m3, background noise - Cz 25;
Measuring the reverberation time (RT60), acoustic evaluation of human voice, determination of absorption coefficient of materials used in construction and industry

- Transmissibility Chambers (according to ISO 10140-1)
Determination of sound insulation index for walls Rw and to impact Ln,w



- Acoustic camera SoundCam Bionic M.
Real-time sound source localisation, noise analysis

- Vibrations analyser ACOEM FALCON
Equilibration, diagnosis and monitoring of the condition of rotating machines, vibrations analysis

- Test bench and diagnosis of rotating machines
Analysis of vibrations of rotors by introducing loads on bearings, of imbalance, misalignment, and of gearing faults.

- Software facilities
IMMI – Woelfel - developing noise maps
Actran – MSC – numerical simulations
ARTeMMIS – modal analysis
DEWEsoft – data processing and noise and vibrations analyses
dBFA – data processing and noise analysis